Armature Windings of Alternators


The armature windings in alternators are different from those used in d.c. machines.

Difference between Armature windings of DC Machines and Alternators

The d.c. machines have closed circuit windings but alternator windings are open, in the
sense that there is no closed path for the armature currents in the winding itself.

One end of the winding is joined to the neutral point and the other is brought out (for a star-connected armature).

types of armature windings


The two types of armature windings most commonly used for 3-phase alternators are :
(i) single-layer winding
(ii) double-layer winding


Single-layer Winding


It is variously referred to as concentric or chain winding.


Sometimes, it is of simple bar type or wave winding.


The fundamental principle of such a winding is illustrated in Fig below.

which shows a single-layer, one-turn, full-pitch winding for a four-pole generator.

Alternator-windings

There are 12 slots in all, giving 3 slots per pole or 1 slot/phase/pole.

The pole pitch is obviously 3.

To get maximum e.m.f., two sides of a coil should be one pole-pitch apart i.e. coil span should
be equal to one pole pitch.

In other words, if one side of the coil is under the centre of a N-pole, then the, other side of the same coil should be under the centre of S-pole i.e. 180ยฐ (electrical) apart.

In that case, the e.m.fs. induced in the two sides of the coil are added together.

It is seen from the above figure, that R phase starts at slot No. 1, passes through slots 4, 7 and
finishes at 10.

The Y-phase starts 120ยฐ afterwards i.e. from slot No. 3 which is two slots away from the start of R-phase (because when 3 slots correspond to 180ยฐ electrical degrees, two slots correspond to an angular displacement of 120ยฐ electrical).

It passes through slots 6, 9 and finishes at 12. Similarly, B-phase starts from slot No.5 i.e. two slots
away from the start of Y-phase.

It passes through slots 8, 11 and finishes at slot No. 2, The developed diagram is shown in Fig. given below

5E0D6FE6 EA86 4DA4 A145 741E59B395D4

The ends of the windings are joined to form a star point for a Y-connection.

Concentric or Chain Windings


For this type of winding, the number of slots is equal to twice the number of coils or equal to the number of coil sides.

In Fig. given below is shown a concentric winding for 3-phase alternator. It has one coil per pair of poles per phase.

BAD2EAC3 79D9 459E 984A 342A3E5D60E3


It would be noted that the polar group of each phase is 360ยฐ (electrical) apart in this type of winding

  1. It is necessary to use two different shapes of coils to avoid fouling of end connections.
  2. Since polar groups of each phase are 360 electrical degrees apart, all such groups
    are connected in the same direction.
  3. The disadvantage is that short-pitched coils cannot be used.

Another type is aconcentric winding with two coils per group per pole.


Different shapes of coils are required for this winding.


All coil groups of phase R are connected in the same direction. It is seen that in each group, one coil has a pitch of 5/6 and the other has a pitch of 7/6 so that pitch factor (explained later) is 0.966.

Such windings are used for large high-voltage machines.

Two-Layer Winding


This winding is either of wave-wound type or lap-wound type (this being much more common especially for high-speed turbo-generators).

It is the simplest and, as said above, most commonly-used not only in synchronous machines but in induction motors as well.

Two important points regarding this winding should be noted :


(a) Ordinarily, the number of slots in stator (armature) is a multiple of the number of poles and the
number of phases. Thus, the stator of a 4-pole, 3-phase alternator may have 12, 24, 36, 48 etc.
slots all of which are seen to be multiple of 12 (i.e. 4 ร— 3).


(b) The number of stator slots is equal to the number of coils (which are all of the same shape).
In other words, each slot contains two coil sides, one at the bottom of the slot and the other
at the top. The coils overlap each other, just like shingles on a roof top.

Electrical Machines Best Books

Sl no.Book
Title
AuthorBuy Link
1Textbook Of Electrical Technology :
Ac And Dc Machines (volume – 2)
B L Theraja, AK Therajacheck price
2Theory & Performance of Electrical MachinesJ.B. Guptacheck price
3Electrical Machinesby V.K Mehta, Rohit Mehtacheck price
4Electric MachinesPS Bimbhracheck price
5Electrical MachinesS.K. Bhattacharyacheck price

Leave a Comment

error: Content is protected !!